Test Bench: Pioneer Kuro PDP-5010FD 50-inch Plasma HDTV

Color temperature (User Mode/Low Color Temperature):
20 IRE: 6,109 K
30 IRE: 6,446 K
40 IRE: 6,418 K
50 IRE: 6,425K
60 IRE: 6,455 K
70 IRE: 6,463 K
80 IRE: 6,429 K
90 IRE: 6,445 K
100 IRE: 6,441K
Brightness (100-IRE window): 31 ftL

Primary Color Point Accuracy vs. SMPTE HD Standard

Color Target X Measured X Target Y Measured Y
Red 0.64 0.71 0.33 0.32
Green 0.30 0.27 0.60 0.66
Blue 0.15 0.13 0.06 0.04

After I made basic picture adjustments in the User mode with the Low color-temperature preset selected, the Pioneer's grayscale tracked within 82 degrees kelvin of the 6,500-K standard from 30 to 100 IRE. Such stellar out-of-box grayscale performance is rare: I can literally count on one hand the number of TVs I've tested that have come near. The set's Movie preset also delivered a reasonably accurate grayscale, tracking within -200 degrees K of the 6,500-K standard from 20 to 100 IRE. Color-decoder tests revealed a mild -5% red error on the HDMI and component-video inputs. Compared with the SMPTE HD specification, red and green color points showed moderate levels of oversaturation.

Overscan - the amount of picture area cut off at the edges of the TV's screen - measured 0% for 1080i/p high-definition signals when the Dot-by-Dot mode was selected and 3% in Full mode. The PDP-5010FD displayed 1080i/p and 720p test patterns with full resolution via its HDMI connections, although alternating black and white lines in the highest-frequency burst from a 1080i pattern showed little contrast when viewed via component video. Screen uniformity and off-axis viewing angle were both excellent. Reflectivity could be an issue, however, with some glare showing up onscreen during daytime viewing.

The set passed both the video- and film-mode deinterlacing tests on the Silicon Optix HQV DVD test disc. Nor did it have any problem with 2:3 film pulldown on regular movie DVDs, although the processing was slow to kick in on test patterns. The TV's 3D noise-reduction setting proved very effective in cleaning up grainy images without eliminating detail. Its Field noise-reduction setting tended to blur fine picture detail when set to Medium or High, however.

Full Review
Test Reports RSS Feed
More Test Reports
Back to Homepage
What's New on S&V

Post a Comment
(1500 Characters or less)
CAPTCHA
This question is for testing whether you are a human visitor and to prevent automated spam submissions.
By submitting this form, you accept the Mollom privacy policy.
All submitted comments are subject to the license terms set forth in our Privacy Policy and Terms of Use